Injecting system used to protect against rising dampness.

TEAIS CAPI C, sistema de inyectores

¡Compártelo o guárdalo!

TEAIS CAPI C, sistema de inyectores , Injecting system used to protect against rising dampness.

TEAIS CAPI C, sistema de inyectores

Injecting system used to protect against rising dampness.

Description Injecting system used to protect against rising dampness., TEAIS CAPI C, sistema de inyectores ?

System used to protect against rising dampness. TEAIS CAPI C consists of injectors that are place in walls that are affected by rising dampness. The injected liquid has a high capacity of penetration into the wall curing in humid environments. This system allow to repair walls made of stone, concrete, solid and hollow bricks, etc.

Aplication Injecting system used to protect against rising dampness.?

TEAIS CAPI-C is used to create a blocking effect so as to protect against rising dampness in wall made of different materials such as stobe, hollow brick, sold brick, etc.

Features and Benefits de TEAIS CAPI C, sistema de inyectores , Injecting system used to protect against rising dampness.

  •  GREAT PENETRATING POWER
  •   GREAT FLUIDITY
  •   EXCELLENT BLOCKING PROPERTIE
  •   CAN POLYMERIZED IN WET ENVIRONMENTS
  •   RESISTANT TO ALKALINE COMPOUNDS
 COMPRAR

¡Compártelo o guárdalo!

Surface preparation

The support of application must be cleaned by removing 20 cm thick layer above the level of dampness. In those cases of extreme dampness, holes are drilled so as to enable ventilation.

Modes of application Injecting system used to protect against rising dampness.?

  Remove around 20 cm thick layer above the level of dampness. - In those cases of extreme dampness, holes of 25 mm diameter approximately are drilled so as to enable ventilation. - These holes allow the wall to dry and will be left for more time in certain cases for which specially designed baseboards will be used so as to ensure ventilation. - Holes are done with a 12 mm drill at every 15 cm height from floor level, being the same as the wall width. The depth of the hole is half the thickness of the support. - Place an injector in each hole and leave until it empties. - Fit the nozzle to each injector, by making a hole in the tube with the cap so as to enable the injection of the fluid through the fitted nozzle.
  The tubes are suitably placed on the wall with special fixings. In case it is not possible to place mechanical fixings, a stand will be set up so as to hold the tubes in place for injection. - No definite time is estimated for injection since it will depend on the degree of humidity of the support and its porosity. - Injection with TEAIS CAPI-C must be done by ensuring proper ventilation and air renewal.

Clean up

Tools must be cleaned using DISOLUAIS.

Performance Injecting system used to protect against rising dampness.

1 injector of 400 cc each 15 cm approx.

Storage Injecting system used to protect against rising dampness.

1 year in their orginal packages tightly closed, protected from the weather and stored in a cool and dry place.

Documentation Injecting system used to protect against rising dampness.

Productos relacionadas

MÁXIMA CALIDAD.
En materias primas
y construcción.
FEDER INNTERCONECTA

2015-2017 SHIAC (ITC-20151250): DESARROLLO DE TECNOLOGÍAS DE HIGIENIZACIÓN PARA LA REDUCCIÓN DE RIESGOS BIOLÓGICOS EN ACUICULTURA
El proyecto SHIAC tiene como objetivo principal la investigación y desarrollo de una estrategia integral que permita reducir el riesgo biológico en acuicultura, integrando diferentes medidas tanto de tipo activo como pasivo para la prevención de patologías con una gran incidencia económica en el sector, y aportando soluciones más sostenibles ambientalmente a las actualmente empleadas en acuicultura.
Grupo Tres Mares S.A actúa como socio representante del consorcio empresarial que ejecuta este proyecto el cual ha sido aprobado y subvencionado por CDTI en el marco de la convocatoria FEDER INNTERCONECTA 2015.